City of Bountiful (UT)
Codes
- NEC Code Version
- 2017
- Fire Code Version
- 2018 Building Code
- Code List
2017 NATIONAL ELECTRICAL CODE
2021 INTERNATIONAL FIRE CODE
2018 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL RESIDENTIAL CODE
2018 INTERNATIONAL ENERGY CONSERVATION CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 1
- Revision Required
- 1
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes,Yes - Battery
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 103
- Wind Notes
https://ascehazardtool.org/
- Snow Load
- 57
- Snow Load Notes
https://ascehazardtool.org/
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,Meter Adapter,Load Side Taps,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Electrical photos are required on plans - dead front on & off, panel label, 10' on sides, Meter/Main Disconnect Photo. Photos needs to show wall space from ground level to wight feet high so AHJ can See any possible obstructions. show the outside area where all the New equipment will be mounted.
- Site
**BATTERY JOBS:** * There needs to be an external to the home mounted, physical, lockable disconnect between the meter / main disconnect and the Tesla Gateway panel.
- Electrical Diagram
When a production meter is required, it should be placed between the AC disconnect and the main panel to allow the PV meter to stay energized when the disconnect is killed. INV -> AC -> PM -> MSP.
- Electrical Diagram Notes
Electrical photos are required on plans - dead front on & off, panel label, 10' on sides, Meter/Main Disconnect Photo. Photos needs to show wall space from ground level to wight feet high so AHJ can See any possible obstructions. show the outside area where all the New equipment will be mounted.
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim