Entergy Arkansas
Net metering & export
- Net Metering Allowed
- 0
- NEM Type
- N/A
- Post Solar Billing Method
- Export Rate
- Solar Export Type
- Avoided Cost
- Solar Export Rate Approx
- 0.0259
- Net Excess Generation Notes
The Company shall separately meter, bill, and credit each Net-Metering Facility even if one (1) or more Net-Metering Facilities are under common ownership. If the kWhs generated by the Net-Metering Facility and fed back to the Company during the Billing Period exceed the kWhs supplied by the Company to the Net-Metering Customer during the applicable Billing Period, the Company shall credit the Net-Metering Customer with any accumulated Net Excess Generation in the next applicable Billing Period. Net Excess Generation credits remaining in a Net-Metering Customer’s account at the close of a billing cycle shall not expire and shall be carried forward to subsequent billing cycles indefinitely. For Net Excess Generation credits older than twenty-four (24) months, a Net-Metering Customer may elect to have the Company purchase the Net Excess Generation Credits in the Net-Metering Customer’s account at the Company’s Avoided Cost plus any additional sum determined under the Net Metering Rules if the sum to be paid to the Net-Metering Customer is at least one hundred dollars ($100). The Company shall purchase at the Company’s Avoided Cost, plus any additional sum determined under the Net Metering Rules any Net Excess Generation Credits remaining in a Net-Metering Customer’s account when the Net-Metering Customer: 1) ceases to be a customer of the Company; 2) ceases to operate the Net-Metering Facility; or 3) transfers the Net-Metering Facility to another person. When purchasing Net Excess Generation credits from a Net-Metering Customer, the Company shall calculate the payment based on its Avoided Costs plus any additional sum determined under the Net-Metering Rules for the current year.
- Rebates Offered
- 0
- Deregulated
- 0
- Allows Standby
- 0
Interconnection & taps
- Approval Req To Install
- Yes
- Interconnection Level
- 1
- Supply Side Taps Allowed
- 1
- Line Taps Allowed
- 0
- Load Taps Allowed
- 1
- Tap Criteria
Load Side Taps allowed, Line Side Taps are NOT allowed.
Entergy does not allow taps between the main breaker and the meter. AKA NO LINE SIDE TAPS
- Automatic Transformer Upgrade Size
- 0
- Meter Aggregation Allowed
- 1
System size & offset
- System Size Restrictions
- 25
- System Size Restriction Type
- AC kW
- System Size Battery Included
- 0
- System Size Includes Existing Systems
- 0
- Offset Type
- Combination
- Offset Value
- 100
- Offset Calculation Basis
- Historical
- Offset Calculation Period
- 12
- Industry Standard Watts Sqft
- 2
- System Offset Notes
System offset limited to the lesser of the following:
- Generation to be less than or equal to the customer’s usage for the past 12 months
- 25 kW AC
- Offset Calc Tool
- Historical Usage
Metering & disconnect
- Production Meter Required
- No
- Production Meter Position
- N/A
- Production Meter Labeling
- N/A
- Meter Spot Process
If the customer requires a temporary disconnect, the customer must call the 800 number and request it.
Customer will need to call 48 hours in advance.
- Allowed Meter Adapter
- None
Plans & docs
- SLD Reqs
Have a clearly labeled manual disconnect switch approved by the utility; location of the disconnect switch must be indicated on the one-line diagram.
- Install Reqs
Metering equipment shall be installed to both accurately measure the electricity supplied by the Electric Utility to each Net-Metering Customer and also to accurately measure the electricity generated by each Net-Metering Customer that is fed back to the Electric Utility over the applicable Billing Period. If nonstandard metering equipment is required, the customer is responsible for the cost differential between the required metering equipment and the utility’s standard metering equipment for the customer’s current rate schedule.
Install a meter socket for the Company’s meter and any related interconnection equipment per the Company’s technical requirements, including safety and performance standards
- Placards
Customer shall label meter can with type and size of generator with arrow pointing to it stating distance to disconnect. (Example 300kVA Gas engine generator, 3 ft.) Permanently attached tags are required. The lettering on each tag shall be 3/16 inch or larger and be either raised or incised on each tag. Each tag shall be riveted or glued to the meter can.
- Equipment Approvals
- California Energy Commission
- Website
- link
- Phone
- (800) 368-3749
Other details
- Restrict Inspection
- 0
- Revision Required
- 1
- Mod Swap Requires Planset
- 1
- Address ID
- 694556
- Express Planset Eligible
- Yes