SDG&E - San Diego Gas and Electric

California Utility Interconnection & net metering rules
Net Metering Allowed0
NEM TypeN/A
Supply Side Taps Allowed0
Line Taps Allowed0
Load Taps Allowed0
AC Disconnect RequiredSituational

Net metering & export

Net Metering Allowed
0
NEM Type
N/A
TOU Utility
1
Post Solar Billing Method
Export Rate
Solar Export Type
N/A
Net Excess Generation Notes


Rebates Offered
1
Allows Standby
1

Interconnection & taps

Approval Req To Install
No
Interconnection Level
2
Supply Side Taps Allowed
0
Line Taps Allowed
0
Load Taps Allowed
0
Automatic Transformer Upgrade Size
0
Meter Aggregation Allowed
1

System size & offset

System Size Restrictions
0
System Size Restriction Type
No Restrictions
System Size Battery Included
0
System Size Includes Existing Systems
0
Offset Type
Percentage
Offset Value
150
Offset Calculation Basis
Historical
Offset Calculation Period
12
Industry Standard Watts Sqft
2
Inverter Oversize Restrictions
0
System Offset Notes


Offset Calc Tool
N/A

Metering & disconnect

Production Meter Required
No
Production Meter Position
N/A
Production Meter Labeling
N/A
AC Disconnect Required
Situational
AC Disconnect Criteria
  • PV system size is over 30 kW
  • Battery projects
AC Disconnect Labeling
Visible Lockable Labeled Disconnect
Meter Spot Required
1
Meter Spot Process

Meter Spot Request Form

  • Fill out the service request form online
  • Review can take 14-16 weeks for actual service order to be obtained. (https://serviceform.extweb.sempra.com/)
  • SOP / Emails attached below for further process information.

SDG&E Planning Offices

  • North East Region:
  • North Coast Region:
  • Eastern Region:
  • Metro Region:
  • Beach Cities Region:
  • Orange County:
  • Mountain Empire District: (email request as well or it will take 30 days just to receive)
Allowed Meter Adapter
RMA,Tesla Backup Switch

Plans & docs

Site Plan Reqs

Battery Projects

  • INCLUDE NOTE THAT INDICATES THE MODE OF OPERATION FOR THE BATTERY, (backup, solar self-consumption, etc.).
  • Battery must have a readily accessible disconnect (AC or DC, depending on system type)
  • If batteries are installed in the garage, a heat / smoke detector is required to be installed above the batteries. This must be shown on the site plan.
  • Unable to use Tesla Backup Switch on meter-gangs / multimeter services.
SLD Reqs

All Jobs

  • INCLUDE NOTE THAT INDICATES THE MODE OF OPERATION FOR THE BATTERY, (backup, solar self-consumption, etc.)
  • Single Line Diagram to reflect Phase, voltage, and ampacity for the Utility Service Panel. 

Tesla BUS

  • Not approved on multi-meter panels.

Over 10kW

  • CALL OUT the Short Circuit Interrupting Rating (SCIR)

HOT BUS, NO MB

  • If no main breaker is present (e.g. hot bus), provide the rating of each circuit breaker in the MSP. "To Other Loads" is insufficient.
Placards

Battery Projects

  • Battery must be shown on the placard and labeled “Battery,” not the manufacturer name. “Tesla” or “SolarEdge” will be rejected.
  • For Powerwall 3, the placard must specify 'BATTERY/INVERTER' as it is a combined unit.

Existing Systems

  • The placard must include both systems, as the existing (E) placard will be removed.

All Jobs

  • The disconnect placard must state “PV system disconnect for utility operation.” (If applicable)
Electrical Stamp Required
0
Meter Num Req SLD 3LD
0
ESID Num Req SLD 3LD
0
Electrical Diagram Notes

All Jobs [PER CEC 705.12(D)(1) INTERCONNECTION SHALL BE MADE AT A DEDICATED CIRCUIT BREAKER OR FUSIBLE DISCONNECT.]

Rate Schedule Link
link
Website
link
Phone
(800) 411-7343

Other details

Restrict Inspection
0
Revision Required
0
Mod Swap Requires Planset
0
Address ID
109471
Express Planset Eligible
Yes