City of Milford

Delaware Utility Interconnection & net metering rules

Spot something wrong?

Tariffs and interconnection rules move often. If something here is out of date or missing, tell us and we'll fix it.

Report a correction
Net Metering AllowedYes
NEM TypeAnnual
Line Taps AllowedNo
Load Taps AllowedNo
AC Disconnect RequiredNo

Net metering & export

Net Metering Allowed
Yes
NEM Type
Annual
TOU Utility
No
Post Solar Billing Method
Net Metering
Solar Export Type
Other
Solar Export Rate
0.12
Net Excess Generation Notes

NOTE: * SB298 signed on 7/22/22 amended Title 26 of DE Code Net Metering; increased utility cap from 5% to 8%; once the 8% cap has been reached, new solar customer will no longer be eligible for the NEM program


Customers to be credited in kilowatt-hours (kWh) for any excess production of their generating facility that exceeds the customer’s on-site consumption of kWh in a billing period (an “Excess kWh Credit”). Excess kWh Credits shall be credited to subsequent monthly billing periods to offset a customer’s consumption in those billing periods. Excess kWh Credits at the end of the annualized billing period shall revert to the electric distribution company providing electric distribution to the customer.

Rebates Offered
No
Deregulated
No

Interconnection & taps

Approval Req To Install
Yes
Line Taps Allowed
No
Load Taps Allowed
No
Automatic Transformer Upgrade Size
0
Meter Aggregation Allowed
Yes

System size & offset

System Size Restrictions
25
System Size Restriction Type
AC kW
System Size Battery Included
No
System Size Includes Existing Systems
No
Offset Type
Combination
Offset Value
100
Offset Calculation Basis
Average
Offset Calculation Period
24
Industry Standard Watts Sqft
2
System Offset Notes

The system size is based on the customer’s most recent two-year average (last 24 months) energy consumption. The average takes into account any statistically outlying months. The system production must be less than 110% of this annual average. If there is no history for the location the City of Milford will provide an estimate based on similar neighborhood houses and situations. The City will not approve an oversized system resulting in the customer becoming a generator.


To be eligible for the net metering service, the generating capacity of a system cannot exceed the customer’s annual electric energy needs. Systems over 25kW may require a pre-interconnection study and other requirements as described in the City of Milford electric rules and regulations

Offset Calc Tool
Historical Usage

Metering & disconnect

Production Meter Required
No
Production Meter Position
N/A
Production Meter Labeling
N/A
AC Disconnect Required
No
AC Disconnect Labeling
Utility Disconnect Switch
Allowed Meter Adapter
None

Plans & docs

Site Plan Reqs

Plans must be stamped

SLD Reqs

Plans must be stamped

Electric Service Reqs

Utility Meter:

The utility meter must be located on the structure adjacent to the system disconnect device. If the meter is located on a pedestal near the street the meter will need to be moved to the structure by the customer/contractor before the interconnection application will be approved.


Disconnect:

The City of Milford requires a system disconnect device be installed adjacent to the electric meter. This disconnect device must be clearly marked and accessible to the City of Milford at all times.

Electrical Stamp Required
Yes
Equipment Approvals
California Energy Commission
Meter Num Req SLD 3LD
No
ESID Num Req SLD 3LD
No
Rate Schedule Link
link
Website
link
Phone
(302) 422-1110

Other details

Revision Required
Yes
Mod Swap Requires Planset
Yes
Compiled from public records, 2026. Tariffs and interconnection rules change; verify with City of Milford before you rely on this. The useful move: if an installer says you need a main panel upgrade, ask how these tap and interconnection policies were considered first.