DEC - Delaware Electric Cooperative
Net Metering Allowed1
NEM TypeMonthly
Supply Side Taps Allowed1
Line Taps Allowed1
Load Taps Allowed1
AC Disconnect RequiredYes
Net metering & export
- Net Metering Allowed
- 1
- NEM Type
- Monthly
- TOU Utility
- 1
- Post Solar Billing Method
- Net Metering
- Rebates Offered
- 1
- Deregulated
- 1
- Allows Standby
- 1
Interconnection & taps
- Approval Req To Install
- Yes
- Interconnection Level
- 1
- Supply Side Taps Allowed
- 1
- Line Taps Allowed
- 1
- Load Taps Allowed
- 1
- Automatic Transformer Upgrade Size
- 0
- Meter Aggregation Allowed
- 1
System size & offset
- System Size Restrictions
- 0
- System Size Restriction Type
- No Restrictions
- System Size Battery Included
- 0
- System Size Includes Existing Systems
- 0
- Offset Type
- Percentage
- Offset Value
- 110
- Offset Calculation Basis
- Average
- Offset Calculation Period
- 24
- Industry Standard Watts Sqft
- 2
- System Offset Notes
• The largest this system can be without exceeding 110% of their 24 monthly average usages.
• For DEC members that have greater than 12 months of usage history and less than 24 months of usage history, the most recent 12 months of usage history shall be used to obtain the average monthly usage necessary for calculating the inverter size as described in the interconnection agreement. (Available in the files section)
• For systems being installed on properties with less than 12 months of recorded usage, see the below guidelines on maximum system sizes:
- Single-wide trailers: 3.8 kVA
- Double-wide trailers: 6 kVA
- < 2000 sqft house: 6.2 kVA
- 2000 - 3000 sqft house: 8.1 kVA
- 3000+ sqft house: 11.7 kVA
- Offset Calc Tool
- Historical Usage
Metering & disconnect
- Production Meter Required
- No
- Production Meter Position
- N/A
- Production Meter Labeling
- N/A
- AC Disconnect Required
- Yes
- Allowed Meter Adapter
- None
Plans & docs
- Site Plan Reqs
A lockable disconnect device shall be installed within three (3) feet of the DEC meter and accessible at all times by DEC personnel.
- Website
- link
- Phone
- (855) 332-9090
Other details
- Restrict Inspection
- 0
- Address ID
- 208958
- Express Planset Eligible
- Yes