Ocala Electric Utility
Net metering & export
- Net Metering Allowed
- 0
- NEM Type
- Monthly
- Post Solar Billing Method
- Export Rate
- Solar Export Type
- Avoided Cost
- Solar Export Rate Approx
- 0.06
- Solar Export Value Notes
- The calculated rate is based on ARP Renewable Generation Credit Rate/kWh + OEU’s current demand credit. The OEU demand credit value is a temporary incentive credit and is currently $0.06000/k
- Net Excess Generation Notes
Net metering adds a credit to the billing process. The customer will be billed for the total amount of electricity (kWh) delivered to the home by the utility. The customer will then be credited for the total amount of excess electricity (kWh) that is generated by the customer and delivered to the utility at a calculated rate.
Excess generation = First, the customer-owned renewable generation is used to supply the customer’s own electricity usage, offsetting the need for electricity from their utility. When the customer needs more electricity than their system generates, the deficit is purchased from the utility. Conversely, when the customer uses less electricity than their system generates, the surplus is delivered to the utility’s distribution system, metered, and compensated to the customer on future billings as a credit.
- Rebates Offered
- 0
Interconnection & taps
- Approval Req To Install
- Yes
- Interconnection Level
- 3
- Line Taps Allowed
- 0
- Load Taps Allowed
- 1
- Automatic Transformer Upgrade Size
- 0
- Meter Aggregation Allowed
- 0
System size & offset
- System Size Restrictions
- 0
- System Size Restriction Type
- No Restrictions
- System Size Battery Included
- 0
- System Size Includes Existing Systems
- 0
- Offset Type
- Percentage
- Offset Value
- 100
- Offset Calculation Basis
- Historical
- Offset Calculation Period
- 12
- Industry Standard Watts Sqft
- 2
- System Offset Notes
100% - please utilize the utility's sizing calculator found here:
https://www.ocalafl.gov/home/showpublisheddocument/18620/638205324725230000
- For projects with existing system, enter the net kWh consumption (not the total consumption).
- The calculator will provide the maximum AC kW system - their AC system is equivalent to DC Size * 0.85
- Offset Calc Tool
- Utility Tool
Metering & disconnect
- Production Meter Required
- No
- Production Meter Position
- N/A
- Production Meter Labeling
- N/A
- Allowed Meter Adapter
- None
Plans & docs
- Electric Service Reqs
System Size:
* The RGS GPR must not exceed 90% of the customer's distribution rating at the customer's location.
Equipment, installation, operation and maintenance is in compliance with several Net Metering standards, including:
* IEEE 1547 (2003): Standard for Interconnecting Distributed Resources with Electric Power Systems
* IEEE 1547.1 (2005): Standard Conformance Test Procedures for Equipment Interconnecting Distributed Resources with Electric Power Systems
* UL 1741 (2005): Inverters, Converters, Controllers and Interconnection System Equipment for Use with Distributed Energy Resources The National Electric Code, state and/or local building codes, mechanical codes and/or electrical codes The manufacturer’s installation, operation and maintenance instructions
Taps:
* Please contact the Meter Division if you should need access to the meter can. .
- Rate Schedule Link
- link
- Website
- link
- Phone
- (352) 629-2489