Sumter EMC
Net metering & export
- Net Metering Allowed
- 0
- TOU Utility
- 0
- Post Solar Billing Method
- Export Rate
- Solar Export Type
- Avoided Cost
- Net Excess Generation Notes
The rates paid or credited to the Member Generator for net energy purchased by the Cooperative shall be based upon the Cooperative’s avoided cost of energy. The avoided cost of energy shall be applied monthly at the rate of $0.04055 per kWh.
- Rebates Offered
- 0
- Deregulated
- 0
Interconnection & taps
- Approval Req To Install
- Yes
- Interconnection Level
- 3
- Supply Side Taps Allowed
- 0
- Line Taps Allowed
- 0
- Load Taps Allowed
- 0
- Automatic Transformer Upgrade Size
- 0
- Meter Aggregation Allowed
- 0
System size & offset
- System Size Restrictions
- 10
- System Size Restriction Type
- AC kW
- System Size Battery Included
- 0
- System Size Includes Existing Systems
- 0
- Offset Type
- No Restrictions
- Offset Value
- 0
- Offset Calculation Period
- 0
- Industry Standard Watts Sqft
- 2
- System Offset Notes
Metering & disconnect
- Production Meter Required
- No
- Production Meter Position
- N/A
- Production Meter Labeling
- N/A
- AC Disconnect Required
- Yes
- AC Disconnect Labeling
- Visible Lockable Labeled Disconnect
- Meter Spot Process
Temporary Disconnect Reconnect Process (TDR) Call the office and make the request.
TDR - Who to Contact Sumter EMC CS
TDR - Applications/Documents Req N/A
TDR - ETA of notice required for request 1 day
TDR - Who can schedule? Does not matter
TDR - ETA of Utility Scheduling TDR 1 day
- Allowed Meter Adapter
- None
Plans & docs
- SLD Reqs
- Install Reqs
The Member Generator must install a UL approved, visible load break Isolation Disconnect Switch, per NEC Article 705 and additional requirements as set by the Cooperative and stated below, at the Member Generator's expense. In all cases, the Member Generator shall pay the full cost of the installation of the Isolation Disconnect Switch
2. The Isolation Disconnect Switch will be, at all times, readily accessible to the Cooperative's personnel, and in a location acceptable to both the Member Generator and the Cooperative.
3. The Isolation Disconnect Switch shall be capable of being secured in an open position by a lock owned by the Cooperative. If the Cooperative has locked the Isolation Disconnect Switch open, the Member Generator shall not operate or close the Isolation Disconnect Switch.
- Electrical Stamp Required
- 0
- Equipment Approvals
- California Energy Commission
- Meter Num Req SLD 3LD
- 0
- ESID Num Req SLD 3LD
- 0
- Rate Schedule Link
- link
- Website
- link
- Phone
- (229) 924-8041
Other details
- Restrict Inspection
- 0
- Address ID
- 209383
- Express Planset Eligible
- Yes