Fayetteville Public Works Commission

North Carolina Utility Interconnection & net metering rules
Net Metering Allowed0
Supply Side Taps Allowed0
Line Taps Allowed1
Load Taps Allowed1
AC Disconnect RequiredYes

Net metering & export

Net Metering Allowed
0
TOU Utility
0
Post Solar Billing Method
Export Rate
Solar Export Type
Other
Solar Export Rate
0.0643
Solar Export Value Notes
See Net Excess Generation Explanation
Net Excess Generation Notes

Effective 05/01/2023

Renewable Energy Buy Back (REBB) 10 kW AC or Less

  • Allows for home or business to utilize energy generated by solar equipment first and exports excess to PWC’s electric grid
  • Customer receives monthly bill credit for all exported energy ($0.06348 per kWh)
  • Excess production does not carry forward to the next month’s bill

Buy All Sell All (BASA) 10.01 kW AC to 20 kW AC

  • Customer receives credit for all energy generated at BASA customer credit rate ($0.0623 per kWh)
  • Excess production that cannot be credited during the billing period does carry over and will be applied to future month’s energy charges
Rebates Offered
0
Deregulated
0
Allows Standby
0

Interconnection & taps

Approval Req To Install
Yes
Interconnection Level
3
Supply Side Taps Allowed
0
Line Taps Allowed
1
Load Taps Allowed
1
Automatic Transformer Upgrade Size
0

System size & offset

System Size Restrictions
20
System Size Restriction Type
AC kW
System Size Battery Included
0
System Size Includes Existing Systems
0
Offset Value
0
Offset Calculation Period
0
Industry Standard Watts Sqft
2
System Offset Notes
  • Max System Size: 20.00 kW AC
Offset Calc Tool
N/A

Metering & disconnect

Production Meter Required
Situational
Production Meter Criteria
  • 10 kW AC or Less: No production meter
  • Over 10 kW AC: Production meter required
AC Disconnect Required
Yes
AC Disconnect Labeling
Visible Lockable Labeled Disconnect
Allowed Meter Adapter
None

Plans & docs

Site Plan Reqs
  • Disconnect must be installed immediately adjacent to the meter for the PV system
  • Disconnect must be accessible to the utility at all times

Note regarding battery projects:

  • PV systems with storage are prohibited from injecting stored energy into PWC's electric grid.
  • Integrated energy storage must be configured to prohibit the export of power. Systems found injecting stored energy will be disconnected without notice and will remain disconnected until it can be demonstrated that the energy storage has been reconfigured to restrict the flow of power to the grid
SLD Reqs

Requirements:

  • Phases, neutral and ground
  • Equipment
  • Fusing
  • Points of connection
  • Disconnects - DC and AC
  • Array wiring
  • Equipment grounding
  • Meter base labeling
  • Physical arrangement of metering and disconnect distance in feet between the isolation switch (PV A/C disconnect) and customer meter. The disconnect must be lockable, heavy duty, fused, and sized per the NEC.
Install Reqs

Completed photos of the equipment (BOS), taken when placards are installed

Placards
  • Disconnect must be labeled in accordance with NEC 705.10
  • A permanent warning label must be placed in a conspicuous place in close proximity to the electric meter or on the meter base to notify Utility personnel that there is a generator installed on the load side of the meter.
  • A warning label must be placed on the Isolation Device
Meter Num Req SLD 3LD
0
ESID Num Req SLD 3LD
0
Website
link
Phone
(910) 223-4600

Other details

Restrict Inspection
0
Revision Required
1
Mod Swap Requires Planset
1
Address ID
1182005
Express Planset Eligible
No