PSE&G - Public Service Electric & Gas
Net Metering Allowed1
NEM TypeAnnual
Supply Side Taps Allowed1
Line Taps Allowed1
Load Taps Allowed1
AC Disconnect RequiredYes
Net metering & export
- Net Metering Allowed
- 1
- NEM Type
- Annual
- Post Solar Billing Method
- Net Metering
- Rebates Offered
- 1
- Allows Standby
- 1
Interconnection & taps
- Approval Req To Install
- Yes
- Interconnection Level
- 3
- Supply Side Taps Allowed
- 1
- Line Taps Allowed
- 1
- Load Taps Allowed
- 1
- Automatic Transformer Upgrade Size
- 0
- Meter Aggregation Allowed
- 0
System size & offset
- System Size Restrictions
- 0
- System Size Restriction Type
- No Restrictions
- System Size Battery Included
- 0
- System Size Includes Existing Systems
- 0
- Offset Type
- Percentage
- Offset Value
- 100
- Offset Calculation Basis
- Historical
- Offset Calculation Period
- 12
- Industry Standard Watts Sqft
- 2
- Utility Specific Adjustments
Load Justification Form (LJF) Requirements
- Required if less than 12 months of usage is available.
- Designers: Complete the appropriate LJF (based on house type) and upload it to the LS files section.
- All LJF forms must be stamped by an engineer. Send completed forms to staff for review and stamping.
Additional Notes
- For Level 2 projects (over 10kW AC), the load calculator must be sealed by a PE.
- To qualify for net metering, system capacity cannot exceed the customer’s annual electric use (100%).
- PV systems cannot be sized based on estimates or future use unless verified by a PE.
- Capacity Map: https://nj.pseg.com/saveenergyandmoney/solarandrenewableenergy/solarpowersustanibility
- System Size Justification
- Load Justification
- System Offset Notes
- Offset Calc Tool
- N/A
Metering & disconnect
- Production Meter Required
- No
- Production Meter Position
- N/A
- Production Meter Labeling
- N/A
- AC Disconnect Required
- Yes
- AC Disconnect Labeling
- Visible Lockable Labeled Disconnect
- Allowed Meter Adapter
- None
Plans & docs
- Site Plan Reqs
- The Address on the plan must match the Utility Bill.
- For all level 2 projects (10 kW AC or above), NJ LJF to be completed and stamped by a PE, See files section for document
- SLD Reqs
- RGM inverter is required
- Electric Service Reqs
- A disconnect switch may be required depending on the size of the installation. It is recommended to be installed on both sides of PSE&G metering for most installations. For Solar Loan Projects, Disconnects are required on both sides of the Utility Meter - Inverter, Production, or SREC.
- Ringed meter sockets need to be replaced with a ringless 5th jaw meter socket
- Install Reqs
- AC disconnect to be installed outside, as close as allowable to existing utility meter, and be fully accessible 24/7 (not behind locked gate etc.)
- Meter Aggregation NOT allowed for residential projects. "Remote Net Metering is only for public entities such as State entity, school district, county, county agency, county authority, municipality, municipal agency, or municipal authority"
- Placards
- For residential service, minimum size is 4” x 4” for Commercial service minimum size is 10” x 10”
- Sign must indicate “Customer Owned Parallel Generation” and location of the safety disconnect
- Sign must be either YELLOW with BLACK lettering, or Red with WHITE lettering
- Location is a minimum of 8’ from grade level and within 2’ of the service point of attachment or service pipe.
- Reference "Sign Requirements for Solar Net Installations" in files below.
- Meter Num Req SLD 3LD
- 1
- ESID Num Req SLD 3LD
- 0
- Rate Schedule Link
- link
- Website
- link
- Phone
- (800) 436-7734
Other details
- Restrict Inspection
- 0
- Address ID
- 108146
- Express Planset Eligible
- Yes