PSE&G Long Island

New York Utility Interconnection & net metering rules
Net Metering Allowed1
Supply Side Taps Allowed1
Line Taps Allowed1
Load Taps Allowed1

Net metering & export

Net Metering Allowed
1
Post Solar Billing Method
Net Metering
Net Excess Generation Notes

For a solar installation, we will change the electric meter to a “net meter.” This meter measures electricity flowing in two directions to determine your “net” usage, which is the difference between the amount of power you supply into the energy grid and the amount you get from it. The reading on a net meter runs backwards when you are supplying energy into the grid. If there’s a billing period during which you supplied more power than you used, you’ll earn credits that will reduce future bills.

Rebates Offered
1
Deregulated
0
Allows Standby
1

Interconnection & taps

Approval Req To Install
Yes
Interconnection Level
3
Supply Side Taps Allowed
1
Line Taps Allowed
1
Load Taps Allowed
1
Automatic Transformer Upgrade Size
0

System size & offset

System Size Restrictions
25
System Size Restriction Type
AC kW
System Size Battery Included
0
System Size Includes Existing Systems
0
Offset Type
Combination
Offset Value
110
Offset Calculation Basis
Historical
Offset Calculation Period
12
Industry Standard Watts Sqft
2
Utility Specific Adjustments

DESIGNERS: If we do not have 12 months of usage, then a Load Justification Form will be required. Please fill out the form and upload filled form to LS files section. Form: Long Island Load Justification Form.xlsx

System Size Justification
Load Justification
System Offset Notes

Load Justification Forms



DESIGNERS: If we do not have 12 months of usage, then a Load Justification Form will be required. Please fill out the form and upload filled form to LS files section. Form: Long Island Load Justification Form.xlsx


Residential Net Meter applications for Solar & Wind systems are limited to 25 kW AC and must provide proof of meeting the requirement that the proposed Solar System production is less than 110% of annual load for the residential service.


Samples for all required documents are available for your information at PSEG-LI website. Please see the following link for more information:


https://www.psegliny.com/aboutpseglongisland/ratesandtariffs/sgip/documents

 

Offset Calc Tool
PV Watts

Metering & disconnect

Production Meter Required
No
Production Meter Position
N/A
Production Meter Labeling
N/A
Allowed Meter Adapter
None

Plans & docs

SLD Reqs

A three line diagram for designs proposed on three phase systems, including detailed information on the wiring configuration at the PCC and an exact representation of existing utility service. One line diagrams shall be acceptable for single phase installations

Inverters must be UL 1741 listed. See spec sheets in files section

Equipment Approvals
California Energy Commission
Website
link
Phone
(800) 490-0025

Other details

Restrict Inspection
0
Revision Required
1
Mod Swap Requires Planset
1
Address ID
689523
Express Planset Eligible
Yes