Pacific Power (OR)

Oregon Utility Interconnection & net metering rules

Spot something wrong?

Tariffs and interconnection rules move often. If something here is out of date or missing, tell us and we'll fix it.

Report a correction
Net Metering AllowedYes
NEM TypeAnnual
Supply Side Taps AllowedYes
Line Taps AllowedYes
Load Taps AllowedYes
AC Disconnect RequiredYes

Net metering & export

Net Metering Allowed
Yes
NEM Type
Annual
TOU Utility
Yes
Post Solar Billing Method
Net Metering
Net Excess Generation Notes
  • For net metering systems, the kilowatt-hours (kWh) that you over produce, if any, will be on your bill statement. If you have excess over production, it will apply to future billings within the annual period.
  • Net Metering is only available for projects under 25kW.
Rebates Offered
No
Deregulated
No
Allows Standby
No

Interconnection & taps

Approval Req To Install
Yes
Supply Side Taps Allowed
Yes
Line Taps Allowed
Yes
Load Taps Allowed
Yes
Tap Criteria
  • Line side taps allowed, but not in meter can
Automatic Transformer Upgrade Size
0
Meter Aggregation Allowed
Yes

System size & offset

System Size Restrictions
25
System Size Restriction Type
DC kW
System Size Battery Included
No
System Size Includes Existing Systems
Yes
Offset Type
No Restrictions
Offset Value
0
Offset Calculation Period
0
Industry Standard Watts Sqft
2
Utility Specific Adjustments

TSRF measures sunlight a site receives over a year.

  • To qualify for solar incentives: on-site TSRF ≥75% (Solmetric or similar).
  • To qualify for solar incentives: remote TSRF ≥80% (Aurora or similar).
System Offset Notes


Offset Calc Tool
PV Watts

Metering & disconnect

Production Meter Required
No
Production Meter Position
N/A
Production Meter Labeling
N/A
AC Disconnect Required
Yes
AC Disconnect Labeling
Visible Lockable Labeled Disconnect
Meter Spot Required
Yes
Allowed Meter Adapter
Tesla Backup Switch,ConnectDER

Plans & docs

Site Plan Reqs

All Projects

  • .
  • AC disconnect must be within 10 ft of the utility meter.
  • Trenching may be needed for meters on pedestals or poles; check with local branch.
  • If AC disconnect is on a pole/pedestal, add another AC disconnect for the inverter.
  • Show ETO tilt and orientation for each solar array.
  • Indicate TSRF measurement locations.
  • Label the utility meter on the site plan.

Battery Projects

  • Include local disconnect.
  • Include dedicated AC disconnect near the utility meter and a transfer switch.
  • AC disconnect must be within 10 ft of the utility meter.
SLD Reqs

All Projects

  • .
  • AC disconnect required for generation systems producing >30 amps.
  • Show voltage drop calculations; ETO wiring/voltage drop must be ≤2%.

Battery Projects

  • Include local disconnect.
  • Include dedicated AC disconnect and transfer switch (or equivalent) in the diagram.
Install Reqs


Placards
  • Reference “Placard Sample” and “Site Placard Examples - Pacific Power” in Files.
  • Meter base sign: “Parallel Generation On Site”.
  • AC disconnect sign: “Manual Disconnect for Parallel Generation”.
  • If multiple AC disconnects, add count: “1 of 3”, “2 of 3”, etc.
Electrical Stamp Required
No
Equipment Approvals
California Energy Commission
Meter Num Req SLD 3LD
No
ESID Num Req SLD 3LD
No
Site Plan Notes

All Jobs [AC Disconnect to be within 10ft of Utility Meter]

Label Page Notes
  • On the meter base: “Parallel Generation On Site”
  • On the AC disconnect switch: “Manual Disconnect for Parallel Generation”
Electrical Diagram Notes

All Jobs [AC Disconnect to be within 10ft of Utility Meter]

Website
link
Phone
(800) 625-6078