Claverack Rural Electric Cooperative
Net metering & export
- Net Metering Allowed
- 1
- NEM Type
- Annual
- TOU Utility
- 0
- Post Solar Billing Method
- Net Metering
- Solar Export Type
- Fixed kWh
- Net Excess Generation Notes
Utility Rate: The customer must be on the regular residential (excluding time of use) or seasonal rate. All other rates do not qualify.
The Cooperative bills the member on a monthly basis according to the applicable billing and rate schedules. The Cooperative shall credit an AES at the full retail rate for each kilowatt-hour produced by an AES installed on the member's side of the electric revenue meter, up to a total amount of electricity used by the member during an annual period. If the AES supplies more electrical energy to the cooperative distribution system than the Cooperative delivers to the member in a given billing period, the excess kilowatt hours shall be carried forward and credited against the member's usage in subsequent billing periods at the full retail rate. Any
excess kilowatt hours shall continue to accumulate until the end of the production year. A production year shall be from June 1st through May 31st.
For AES’s involved in virtual meter aggregation, a credit shall be applied first to the meter through which the Cooperative supplies electricity to the distribution system, then through the remaining meters for the AESs account equally at each meter’s designated rate. At the end of each annual period, Allegheny shall compensate the AES for kilowatt-hours generated by the AES over the amount of kilowatt- hours delivered by the Cooperative during the billing period at Allegheny’s avoided cost of
wholesale power. If the calculated amount is under $50, the excess kWh shall be carried forward. Meter aggregation is allowed within a two-mile radius.
- Rebates Offered
- 1
- Deregulated
- 1
Interconnection & taps
- Approval Req To Install
- Yes
- Interconnection Level
- 3
- Line Taps Allowed
- 0
- Load Taps Allowed
- 0
- Automatic Transformer Upgrade Size
- 0
- Meter Aggregation Allowed
- 1
System size & offset
- System Size Restrictions
- 25
- System Size Restriction Type
- AC kW
- System Size Battery Included
- 0
- System Size Includes Existing Systems
- 0
- Offset Type
- Combination
- Offset Value
- 110
- Offset Calculation Basis
- Historical
- Offset Calculation Period
- 12
- Industry Standard Watts Sqft
- 2
- Offset Calc Tool
- Historical Usage
Metering & disconnect
- Production Meter Required
- No
- AC Disconnect Required
- Yes
- AC Disconnect Labeling
- Visible Lockable Labeled Disconnect
- Allowed Meter Adapter
- None
Plans & docs
- Site Plan Reqs
- AC disconnect is required to be accessible to the utility 24/7
- SLD Reqs
- Signed by a licensed Pennsylvania Professional Engineer
- AC disconnect required
- A sample line diagram is available in the database files
- Install Reqs
The contractor must not cut the meter seal on the Claverack Electric meter for any reason during the installation process. Only Claverack Electric employees may pull meters. Contact Claverack Electric if a meter needs to be disconnected temporarily to perform any work. If the meter seal is found to be cut, the member will be charged a $500 tampering fee.
- Electrical Stamp Required
- 1
- Meter Num Req SLD 3LD
- 0
- ESID Num Req SLD 3LD
- 0
- Website
- link
- Phone
- (570) 265-2167
Other details
- Restrict Inspection
- 0
- Revision Required
- 0
- Mod Swap Requires Planset
- 1
- Address ID
- 190166
- Express Planset Eligible
- Yes