YEC - York Electric Cooperative, Inc

South Carolina Utility Interconnection & net metering rules
Net Metering Allowed1
NEM TypeAnnual
Line Taps Allowed0
Load Taps Allowed0

Net metering & export

Net Metering Allowed
1
NEM Type
Annual
TOU Utility
0
Post Solar Billing Method
Net Metering
Net Excess Generation Notes

Excess Generation will be credited monthly by an amount per kWh (4.79 cents). Cooperative shall review the Value of Renewable Generation at least annually to ensure credit reflects the appropriate costs. If the credit is larger than the energy bill, the remaining credit will be retained to offset charges in future billing periods.

Rebates Offered
0
Deregulated
1
Allows Standby
1

Interconnection & taps

Approval Req To Install
Yes
Interconnection Level
1
Line Taps Allowed
0
Load Taps Allowed
0
Automatic Transformer Upgrade Size
0

System size & offset

System Size Restrictions
20
System Size Restriction Type
AC kW
System Size Battery Included
0
System Size Includes Existing Systems
0
Offset Type
Combination
Offset Value
100
Offset Calculation Basis
Historical
Offset Calculation Period
12
Industry Standard Watts Sqft
2
Inverter Oversize Restrictions
1
System Offset Notes

The Nameplate Rating of the member’s installed generation system and equipment must not exceed the lesser of the Member’s actual or estimated maximum annual non-coincidental demand (kW) for the last twelve (12) months or 20 kW or less for residential members and 100 kW or less for nonresidential members.

Offset Calc Tool
PV Watts

Metering & disconnect

Production Meter Required
No
Production Meter Position
N/A
Production Meter Labeling
N/A
Allowed Meter Adapter
None

Plans & docs

Install Reqs

Utility Inspection Required: Yes

Construct the power generating installation system and install a disconnect switch in close proximity to the meter,

warning/safety labels, and other protective equipment as required by IEEE, NEC latest published edition, Facilities and

Operations. A manual load-break disconnect switch or safety switch with a clear visible indication of switch position between the Area EPS and the Generator. The switch must have pad lock provisions for locking in the open position. The switch must be visible to, and accessible to Company personnel. The switch must be in close proximity, and visible from, the Member’s point of electrical interconnection with the Company’s Area EPS. The switch must be labeled “Generator Disconnect Switch”. The switch may isolate the Generator system and its associated load from the area EPS or disconnect only the Generator from the Area EPS."

Placards

"Member will install a permanent warning label in a conspicuous place in close proximity to the electric meter or on the meter base to notify them personnel that there is a generator installed on the load side of the meter. The warning label shall not be placed in a

location that would interfere with the ability of Cooperative personnel to read the electric meter. Member shall also place a warning label on the Isolation Device. Cooperative will provide the warning labels to Member. The warning labels must be in place before the Distributed Resource can be interconnected with Cooperative’s system."

Equipment Approvals
California Energy Commission
Rate Schedule Link
link
Website
link
Phone
(803) 684-4248

Other details

Restrict Inspection
0
Revision Required
1
Mod Swap Requires Planset
1
Address ID
166284
Express Planset Eligible
Yes
Compiled from public records, 2026. Tariffs and interconnection rules change; verify with YEC - York Electric Cooperative, Inc before you rely on this. The useful move: if an installer says you need a main panel upgrade, ask how these tap and interconnection policies were considered first.