Solar Sanity Checksolar, decoded Independent. Nothing you type leaves your browser.

City of Santa Clara, UT

Utah Utility Interconnection & net metering rules
Net Metering Allowed1
NEM TypeMonthly
Line Taps Allowed0
Load Taps Allowed0

Net metering & export

Net Metering Allowed
1
NEM Type
Monthly
TOU Utility
0
Post Solar Billing Method
Net Metering
Net Excess Generation Notes

If the energy supplied by the City exceeds the electricity generated by the Customer and fed

back to the City during the billing period, or any portion thereof, then the customer shall be

billed for:

  1. i. The net energy supplied to Customer by the City’s electric distribution system;
  2. ii. The appropriate customer base charge paid by other customers of the City in the same rate class;
  3. iii. The monthly Solar Reliability Charge as described in Exhibit B.

If the energy generated by Customer and distributed back to the City’s electric distribution

system during the billing period, or any portion thereof, exceeds the energy supplied to the

Customer by the City’s electric distribution system, then the customer shall be:

  1. i. Billed for the appropriate customer service charge as other customers of the City in the same rate class;
  2. ii. Credit for the net excess kWh’s generated during the billing period at the Renewable Power Rate as described in Exhibit B, with this kWh credit appearing on Customer’s bill for the following billing period.
Rebates Offered
0

Interconnection & taps

Approval Req To Install
Yes
Interconnection Level
3
Line Taps Allowed
0
Load Taps Allowed
0
Automatic Transformer Upgrade Size
0
Meter Aggregation Allowed
0

System size & offset

System Size Restrictions
8
System Size Restriction Type
AC kW
System Size Battery Included
0
System Size Includes Existing Systems
0
Offset Type
No Restrictions
Offset Value
0
Offset Calculation Period
0
Industry Standard Watts Sqft
2
System Offset Notes


Metering & disconnect

Production Meter Required
No
Production Meter Position
N/A
Production Meter Labeling
N/A
Allowed Meter Adapter
None

Plans & docs

SLD Reqs

For a 6000 Inverter please use a 40A 2P Breaker. There is a shortage of 35A Breakers - 11.23.20

Website
link
Phone
(435) 673-6712

Other details

Restrict Inspection
0
Address ID
188411
Express Planset Eligible
Yes
Compiled from public records, 2026. Tariffs and interconnection rules change; verify with City of Santa Clara, UT before you rely on this. The useful move: if an installer says you need a main panel upgrade, ask how these tap and interconnection policies were considered first.