Salem City Power (UT)

Utah Utility Interconnection & net metering rules
Line Taps Allowed0
Load Taps Allowed0

Net metering & export

Rebates Offered
0

Interconnection & taps

Approval Req To Install
Yes
Interconnection Level
3
Line Taps Allowed
0
Load Taps Allowed
0
Automatic Transformer Upgrade Size
0

System size & offset

System Size Battery Included
0
System Size Includes Existing Systems
0
Offset Value
0
Offset Calculation Period
0
Industry Standard Watts Sqft
2

Metering & disconnect

Production Meter Required
Yes
Production Meter Position
Inv-Disco-PM-POI
Production Meter Labeling
Production Meter
AC Disconnect Labeling
Visible Lockable Labeled Disconnect
Allowed Meter Adapter
None

Plans & docs

Site Plan Reqs

A detailed site plan showing the location of the home

Electrical meter panel,

Any back fed sub-panelboards, and

All PV system components on the property is required.

Fire set back’s need to be indicated on roof plan.

Mounting System:

Provide detailed information on the module mounting system and also the weight of all components on the roof. The support manufacture specs must also specify the required support spacing based on the local wind and snow loads.

Note if the home roof rafters are engineered trusses or provide information on the type and size of the roof rafters if they are other than engineered trusses.

Also note the type of the roof covering (shingles, metal, or tile) and how many layers of the covering there are. If the racking system has integrated grounding/bonding, please also provide spec sheets showing such.

SLD Reqs

PV Production Meter Required indicates "(N) Make/Model Single Phase NEMA 3R 600V/100A FORM 2S PV Production Meter" (See Sample in Attached File)

Inverter > AC Disconnect > PV Production Meter > MSP

The type of PV system being installed (a single inverter system with one or more strings of modules connected in series, a micro inverter system, or an AC module system),

The exact number and layout of modules and how they are connected together (in series or in parallel),

All wire types, all wire sizes, conduit types and sizes, detailed info on the grounding wiring and connections, the locations of all circuits and system components on or in the house, and the ratings of all fuses or breakers.

The location of the AC, non fused, disconnect, the location of the production meter and the location and size of the PV breaker and indicate line or load side connection.

If a feeder connection is to be done. Provide connection details, equipment and feeder line sizing.

Provide the location and type is signage and labels to be used.

Provide junction box and flashing equipment listing and type to be used.

Example and location of labeling and signage to be installed.

Total array power: (This is not required for systems with micro inverters) Provide the total amount of watts, amps, volts, open circuit voltage (Voc at the coldest possible outside temperature-see NEC 690.7), and short circuit current that the array can produce.

PLEASE PROVIDE A COPY OF EACH SPEC SHEET IN THE PV PLAN SET:

Module spec sheets: Provide the PV module (solar panels) spec sheets showing the modules’ STC rated watts (Pmp), volts (Vmp), amps (Imp), open circuit voltage (Voc), and short circuit current (Isc). Modules must be listed UL 1703.

Inverter spec sheets: Provide the inverter manufacture spec sheets showing the amount of watts and volts the inverter can safely handle, and also noting what the inverter’s max rated AC output amps and voltage is. Utility tied inverters must be listed as “utility interactive” meeting UL 1741, and have ground fault protection.

System components: Provide information on the different types of components that will be used in the system and how they are to be installed. Also show that all equipment is listed and rated for

For a 6000 Inverter please use a 40A 2P Breaker. There is a shortage of 35A Breakers - 11.23.20

Meter Num Req SLD 3LD
0
ESID Num Req SLD 3LD
0
Rate Schedule Link
link
Website
link
Phone
(801) 423-2770

Other details

Restrict Inspection
0
Address ID
112479
Express Planset Eligible
No