Manitowoc Public Utilities
Net metering & export
- Net Metering Allowed
- 1
- NEM Type
- Monthly
- TOU Utility
- 1
- Post Solar Billing Method
- Net Metering
- Solar Export Type
- Avoided Cost
- Solar Export Rate Approx
- 0.04
- Net Excess Generation Notes
Systems 20 kW or Less AC
The customer shall be billed monthly on a net energy basis. When the energy produced exceeds energy consumed for the billing month, the customer shall be credited for the excess energy volumes at the applicable Avoided Cost Rate(s) identified in the Energy Rates Payment section of Schedule No. Pgs-2.
If, in any month, the customer’s bill has a credit balance of $25 or less, the amount shall be credited to subsequent bills until a debit balance is reestablished. If the credit balance is more than $25, the utility shall reimburse the customer by check upon request. Monthly credits shall be computed by taking the net excess kilowatt-hours produced times the sum of the applicable Energy Charge or Avoided Cost Rate(s).
Systems of 20 kW AC
Export Rate: Time of Use Rates
- Rebates Offered
- 1
Interconnection & taps
- Approval Req To Install
- Yes
- Interconnection Level
- 3
- Line Taps Allowed
- 0
- Load Taps Allowed
- 0
- Automatic Transformer Upgrade Size
- 0
System size & offset
- System Size Restrictions
- 0
- System Size Restriction Type
- No Restrictions
- System Size Battery Included
- 0
- System Size Includes Existing Systems
- 0
- Offset Type
- No Restrictions
- Offset Value
- 0
- Offset Calculation Period
- 0
- Industry Standard Watts Sqft
- 2
- Offset Calc Tool
- N/A
Metering & disconnect
- Production Meter Required
- No
- AC Disconnect Required
- Yes
- AC Disconnect Labeling
- Utility Disconnect Switch
- Allowed Meter Adapter
- None
Plans & docs
- Site Plan Reqs
For all system sizes
Must show the location of the interconnection disconnect switch, adjoining street name, and the street address of the DG facility.
System sizes above 20 kW AC
The site plan must show the location of major equipment, electric service entrance, electric meter, interconnection disconnect switch, and interface equipment.
- SLD Reqs
ANSI symbols shall be used in the one-line schematic diagram to show the following:
(a) Generator or inverter.
(b) Point where the DG facility is electrically connected to the customer's electrical system.
(c) Point of common coupling.
(d) Lockable interconnection disconnect switch.
(e) Method of grounding, including generator and transformer ground connections.
(f) Protection functions and systems.
- Placards
The applicant shall label the interconnection disconnect switch “Interconnection Disconnect Switch" by means of a permanently attached sign with clearly visible and permanent letters. The applicant shall provide and post its procedure for disconnecting the DG facility next to the switch.
- Meter Num Req SLD 3LD
- 0
- ESID Num Req SLD 3LD
- 0
- Website
- link
- Phone
- (920) 683-4600
Other details
- Restrict Inspection
- 0
- Mod Swap Requires Planset
- 1
- Address ID
- 168125
- Express Planset Eligible
- Yes